failure situation 1: if the machine is not powered on
answer: the cause of the failure: 1. the power supply is not connected; 2. the power switch is not turned on; 3. the power switch is burned out; 4. the fuse is burned out. respective maintenance methods: 1. connect the power supply; 2. turn on the power switch; 3. replace the power switch; 4. replace the fuse.
fault situation 2: power on but the machine does not work
answer: the cause of the failure: 1. the emergency switch is not released; 2. the programmable controller (plc) does not work; 3. the programmable controller is burned out; 4. the emergency switch node is burned out. respective maintenance methods: 1. release the emergency switch; 2. check the input power of the programmable controller (plc); 3. replace the programmable controller; 4. replace the emergency switch.
failure situation 3: the heater does not heat up
answer: the cause of the failure: 1. the heater switch does not start; 2. the default value of the temperature controller is too low; 3. the heater switch contact is burned out; 4. the temperature controller (tc) is burned out; 5. the solid state relay (ssr) is burned out; 6. the electric heating tube is burnt out; 7. the heating protection relay r3 is damaged. respective maintenance methods: 1. start the heater switch; 2. increase the default value of the temperature controller; 3. replace the heater switch; 4. replace the temperature controller; 5. replace the solid state relay (ssr); 6. replace the electric heating tube ; 7. replace the solid state relay (r3).
臭氧老化试验箱测试试样的要求
如何来测定变色阳离子交换树脂吸附量?
热风旋转炉的特点、日常维护及保养
深芬仪器CSY-SC8茶多酚检测仪测定标准
分享意大利ATOS比例插装阀维修保养
How to troubleshoot the sealing machine
米线机和冷面机是一样机器么?
固定球阀弹簧预紧浮动式阀座的作用
预防美国massvac真空过滤器结冰的防范措施
西门子调节阀该如何正确清洗
上海百试变压器变比组别测试仪功能优势有哪些?
猴T细胞白血病病毒(STLV)ELISA试剂盒
热力管道接口热熔套,热缩带型号
制氧机氧分析仪选型指南
M-PEG3-OH 三乙二醇甲醚 CAS112-35-6 PROTAC技术分享
千叶豆腐生产机器的选购很简单,3个方法轻松解决
三种典型工业环保设备介绍
土壤肥料养分含量检测仪保护土壤环境
科里奥利质量流量计安装调试及故障处理的问题分析
工业废气处理设备流程